Sign In | Join Free | My himfr.com
Home > Lab Testing Equipments >

650W Cleveland Flash And Fire Point Apparatus 220V ASTM D 92 Standard

    Buy cheap 650W Cleveland Flash And Fire Point Apparatus 220V ASTM D 92 Standard from wholesalers
     
    Buy cheap 650W Cleveland Flash And Fire Point Apparatus 220V ASTM D 92 Standard from wholesalers
    • Buy cheap 650W Cleveland Flash And Fire Point Apparatus 220V ASTM D 92 Standard from wholesalers

    650W Cleveland Flash And Fire Point Apparatus 220V ASTM D 92 Standard

    Ask Lasest Price
    Brand Name : SAMYON
    Model Number : SY
    Certification : ISO
    Price : Can be negotiated
    Payment Terms : Western Union, MoneyGram, , T/T, D/P, D/A
    Supply Ability : 1000 per week
    Delivery Time : 3-5days
    • Product Details
    • Company Profile

    650W Cleveland Flash And Fire Point Apparatus 220V ASTM D 92 Standard

    Petroleum Products Flash And Fire Points Testing And Water Content Testing


    Application

    Petroleum products is widely used in our daily life. So the safety usage is most important. To confirm the different petroleum products flash and fire points, we will do it by the Cleveland open cup method and Pensky-Martens closed cup method, and Rapid equilibrium closed cup method. To check what the water content will affect the features in the liquid petroleum products, then we will determine water content by Coulometric Karl Fischer Titration method.


    Standard

    ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.

    ASTM D1533 Standard Test Method for Water in Insulating Liquids

    ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products,Lubricating Oils and Additives by Karl Fischer Titration.


    SY-3536 Cleveland Open Cup Flash Point Tester

    Parameters:


    ItemNameDetails
    1Temperature measurement rangeroom temperature ~ 400℃
    2Ignition modeCoal gas, nozzle aperture is about 0.8mm
    3Heating devicefurnace heating, no naked fire, explosion prevented.The power is adjustable from 0W to 600W.
    4Maximum power consumption650W
    5Accuracy0.1℃
    6Flash point detecting deviceIt applies the test flame automatically
    7Ambient temperature(15~35)℃
    8Relative humidity=<85%
    9Power supplyAC 220+/-10% V, 50Hz
    10Dimension350mmx290mmx350mm

    Features:

    1. The heating power is continuously adjustable. It can meet requirements of test.

    2. The instrument is fully self-contained complete. The operator can do determination as long as connecting with coal gas or other civil gas.

    3. With fast cooling function, it can improve test efficiency.

    4. It adopts special heating furnace to ensure the safety of test.


    SY-261A Automatic Pensky-Martens Closed-Cup Flash Point Tester

    Parameters:


    ItemNameDetails
    1Igniting device

    1. Igniting source: gas (or other civilian fuels)

    2. Electric ignition. Gas flame diameter: 3.2mm~4.8mm

    2Flash point determinationAmbient to 300℃
    3Repeatability=< 2℃
    4Reproducibility=< 4℃
    5Accuracy0.1℃
    6Heating rate

    Procedure A: (5~6)℃/min,

    Procedure B:(1~1.6)℃/min,

    Automatic control and manually adjustable.

    7Stirring rate

    Procedure A: (90~120)RPM,

    Procedure B: (250+/-10)RPM

    8Ambient temperature=<40℃
    9Maximum power consumption500W
    10Relative humidity=<80%
    11Power supplyAC 220+/-10% V, 50Hz

    Features:

    1. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.

    2. Equipped with prompt function of test date, test time and other parameters.

    3. Simulation tracking displays function curves of heating up and test time.

    4. Equipped with the English prompt function of mis-operation.

    5. Igniting with electric igniting gun, forced air cooling.

    6. Differential coefficient detection. Automatically correct the system deviation.

    7. Automatically open the lid, detect the flash point and print test data.

    8. The test arm rises up and lowers down automatically.


    SY-2122C Coulometric Karl Fischer Titrator

    Parameters:


    ItemNameDetails
    1Maximum power consumption60w
    2Measurement range0.0001% (1ppm) to 100%
    3Sensitivity threshold0.01ugH2O
    4Accuracy

    for 5ug-1mg: +/-2ug

    for >1mg: 0.2%

    5Power supplyAC 220+/-10% V, 50Hz
    6Display mode7.0 inch LCD color large screen touch display
    7Test resultsprinting
    8Ambient temperature5℃~40℃
    9Relative humidity=<85%
    10Dimension385x290x280mm

    Features:

    1. The unique alternating balance isolation detection technology makes the balance detection more rapid, accurate and stable.

    2. It can store 20000 experimental results, easy to query.

    3. The imported 0.5ul injector for calibration is equipped, and the calibration of the instrument is fast and accurate.

    4. It can be used for micro analysis of low content samples with high sensitivity.

    5. The electrolysis circuit adopts advanced PWM pulse width modulation technology, which greatly reduces the power consumption of the whole machine.

    6. Friendly man-machine dialogue, with touch screen man-machine interactive interface.

    7. Display the clock (year, month, day, hour, minute and second) and keep it when power down.

    8. Printer: embedded thermal printer, 36 characters, Chinese characters output, Printing is quieter, faster and clearer.

    9. Program control is adopted to adjust the mixing speed by inputting numbers directly from the interface.

    10. Multiple formula selection, automatic change of display units (ug, mg / L, ppm,%) can be memorized. It can be used for micro analysis of low content samples with high sensitivity.